DRAI
Hi everybody,
with abaqus 6.12 on windows 7-64 bit, I run elastic static analysis with
a model of about 30.000.000 tet elements and about 30.000.000 nodes, it
was written 90.000.000  degrees of freedom, after eliminating issues,
the Input File Processor was succefull, but after about 4 hours from
starting the executable standard there are a messeage saying (problem
with meGUI and C++...) AND  standard.exe aborted with system error code
5296979. please I need help, I need to know what's wrong,

"Abaqus JOB jib
Abaqus 6.12-1
Abaqus License Manager checked out the following licenses:
Abaqus/Standard checked out 5 tokens.
<1019 out of 1024 licenses remain available>.
Begin Analysis Input File Processor
03/08/2013 04:34:31
Run pre.exe
03/08/2013 05:38:07
End Analysis Input File Processor
Begin Abaqus/Standard Analysis
03/08/2013 05:38:07
Run standard.exe
03/08/2013 10:08:55
Abaqus Error: The executable standard.exe
aborted with system error code 529697949.
Please check the .dat, .msg, and .sta files for error messages if the
files
exist.  If there are no error messages and you cannot resolve the
problem,
please run the command "abaqus job=support information=support" to
report and
save your system information.  Use the same command to run Abaqus that
you
used when the problem occurred.  Please contact your local Abaqus
support
office and send them the input file, the file support.log which you just
created, the executable name, and the error code.
Abaqus/Analysis exited with errors"




[Non-text portions of this message have been removed]

Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

AMDPRO
This post has NOT been accepted by the mailing list yet.
Check in .dat file, how much memory is required.
--
An Engineer is Never Limited by Resources
Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

Dave Lindeman
In reply to this post by DRAI
That's an enormous model -- the kind of thing a national lab would run
on a huge cluster.  The error code is almost undoubtedly related to a
memory error.  How many GB of RAM do you have on this machine?

Dave Lindeman
Lead Research Specialist
3M Company
3M Center 235-3F-08
St. Paul, MN 55144
651-733-6383

On 8/15/2013 3:38 AM, DRAI wrote:

>
> Hi everybody,
> with abaqus 6.12 on windows 7-64 bit, I run elastic static analysis with
> a model of about 30.000.000 tet elements and about 30.000.000 nodes, it
> was written 90.000.000 degrees of freedom, after eliminating issues,
> the Input File Processor was succefull, but after about 4 hours from
> starting the executable standard there are a messeage saying (problem
> with meGUI and C++...) AND standard.exe aborted with system error code
> 5296979. please I need help, I need to know what's wrong,
>
> "Abaqus JOB jib
> Abaqus 6.12-1
> Abaqus License Manager checked out the following licenses:
> Abaqus/Standard checked out 5 tokens.
> <1019 out of 1024 licenses remain available>.
> Begin Analysis Input File Processor
> 03/08/2013 04:34:31
> Run pre.exe
> 03/08/2013 05:38:07
> End Analysis Input File Processor
> Begin Abaqus/Standard Analysis
> 03/08/2013 05:38:07
> Run standard.exe
> 03/08/2013 10:08:55
> Abaqus Error: The executable standard.exe
> aborted with system error code 529697949.
> Please check the .dat, .msg, and .sta files for error messages if the
> files
> exist. If there are no error messages and you cannot resolve the
> problem,
> please run the command "abaqus job=support information=support" to
> report and
> save your system information. Use the same command to run Abaqus that
> you
> used when the problem occurred. Please contact your local Abaqus
> support
> office and send them the input file, the file support.log which you just
> created, the executable name, and the error code.
> Abaqus/Analysis exited with errors"
>
> [Non-text portions of this message have been removed]
>
>



[Non-text portions of this message have been removed]

Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

Echeban
This post has NOT been accepted by the mailing list yet.
Check a model with 1 element, or a few elements. If ti runs, your problem is memory. Parallel processing uses much more memory than single processor, so a job that runs on cpus=1 may not run on cpus=4.
Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

Abaqus Users mailing list
In reply to this post by Dave Lindeman
Check a model with 1 element, or a few elements. If ti runs, your problem is memory. Parallel processing uses much more memory than single processor, so a job that runs on cpus=1 may not run on cpus=4.
 
Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

rupertfe
This post has NOT been accepted by the mailing list yet.
In reply to this post by DRAI
Hi,

I know it is a bit late ... but maybe others get this error code too.
In my case the solution (or the problem) was the scratch directory:
By default it is on C:\users ..... Temp. I only had 1 or 2 GB free space on the C HDD so the analysis could not finish ...
In the "edit Job" window under the tab "General" you can choose the scratch directory -> choose a place where you have enough (depending on your analysis, a good guess is the memory required or to minimize I/O in the dat-file) free space.

Hope this helps,
kind regards,
Rupert.
Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

ruiDiogo
This post has NOT been accepted by the mailing list yet.
In reply to this post by DRAI
Hi everyone,

This might not be related to the original difficulty in overcoming system error code 529697949, but I'd just like to share my own experience with it.
I got the same error code in analyses I had previously run in my computer (with success), so I started looking at my computer's memory usage. What I found is that UNDER NO CIRCUMSTANCES should you have any torrent based programs running at the time of your usage of Abaqus. The fluctuations in memory usage caused by seeding/downloading these files are enough to throw Abaqus off, it would seem.
I would therefore advise you to always check the memory usage patterns of your machine before recurring to more drastic measures, and remember, no torrents!

Best regards to all and hope this can help someone,

Rui Diogo
 
Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

Abaqus Users mailing list
In reply to this post by DRAI
Hi I Have a same question about error code 529697949. After changing parameters in Abaqus with a simple model I found out the problem is Predefined Field that I have made. when I deactivate it the job will complete but when the predefined field is active this error will appear. My predefined Fields are the same predefined fields that I have define without any problem. But I don't know what should I do to solve this.
Dom
Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

Re: Abaqus Error: The executable standard.exe aborted with system error code 5296979

Dom
This post has NOT been accepted by the mailing list yet.
Hi, did anybody find a solution with the error code 529697949 and Predefined Field in Abaqus? Thanks
Reply | Threaded
Open this post in threaded view
|  
Report Content as Inappropriate

The executable pre.exe aborted with system error code 529697949

Roya22
This post has NOT been accepted by the mailing list yet.
Hi everybody,
I'm running an uncoupled thermo-mechanical analysis with abaqus 6.12.3 and 32GB of RAM.My model consist of 112 steps and 180,180 hexahedral elements.
 I requested restart file  -because my .odb is very large- and used its separate .ODBs as pre-defined field in mechanical analysis.
Unfortunately, the Input file processor was not successful and I recieved this error:

The executable pre.exe aborted with system error code 529697949

and this warning:

Both the file option and the data line format option are used for the *temperature in the same step. For a given node the values given on the data line will take precedence if op=mod parameter is specified or if op=new parameter is used to specify new values for the removed field

Can anybody help?